Internet connection down

The internet connection was down from 15:30 to 17:45 due to a routing loop created by our service provider, ELI. Apparently, some old routes were inadvertantly loaded at the Tukwilla office during a routine upgrade.

Best Access System Hung

The Best Access license server failed today. No Best application could communicate with it.

KETRON, the computer that hosts Best Access services, also could not contact www.ups.edu or microsoft.com via web browser.

KETRON was rebooted

Trimble Fiber Fails

Security reported Saturday night that the connectivity to Trimble Hall had failed. Several of the residents also reported that the Internet connection had been lost.

Trouble shooting revealed that one of the two fiber strands between McIntyre and Trimble had failed. The service was moved to another pair of fibers and service was restored about 9:30 PM Saturday, April 26th.

Account Management in ACADEMIA Fails III

We attempted to reset RID attributes in Active Direcory for the ACADEMIA domain with the Java-based LDAP browser. Unfortunately, these attributes are read-only and can only be modified by the SYSTEM account.

We decided that we should bring another domain controller online in order to transfer or sieze RID master operations. It was my hope that the presence of another domain controller would force the RID master to issue another pool of RIDs, and clear the problem.

The only real candidate for promotion to domain controller was SCYLD. I obtained permission from Math/CS to promote SCYLD.

FENWICK Down

Fenwick began refusing telnet sessions. When it was rebooted, it failed to boot properly. Upon booting into minimal mode, it was determined that the system disk was full. The OPERATOR.LOG file was deleted, and Fenwick was rebooted, the system booted normally, and telnet sessions were no loger refused.

Merlin2 IO System Problem

On Friday, March 14th the “warning” indicator on Merlin2 was flashing, and the third drive was also flashing yellow. As we were in the middle of the data move from Merlin to Merlin2, we decided to push onward and deal with the problem later.

Today, the OS went BSOD. The server was shut down, then powered back up. The server came back up without any data loss and automatically started rebuilding the array onto the previously failed disk.
Continue reading